Steady Heat Conduction
At steady state, a thermal-resistance network turns geometry, materials, interfaces, and fluid films into an auditable map of heat flow.
The analogy is powerful only when the heat paths and areas match the physical system. We develop series and parallel networks, curved walls, critical insulation radius, fins, and shape factors with explicit applicability checks.
Learning objectives
- Construct steady one-dimensional thermal-resistance networks from physical heat paths.
- Compute interface temperatures and identify dominant resistances.
- Select plane, cylindrical, spherical, contact, and convection resistances with correct areas.
- Judge when insulation or fins increase useful performance.
- Audit networks by node balances, units, limits, and correlation/property validity.
Steady Heat Conduction in Plane Walls
For steady one-dimensional, source-free heat flow, each element obeys \(\dot Q=\Delta T/R\). Series elements carry the same rate; parallel paths share the same node-to-node temperature difference. This requires well-defined approximately isothermal nodes.
Thermal Resistance Analogy
Steady heat flow obeys a relation identical in form to Ohm's law: the driving temperature difference equals the heat rate times a thermal resistance. Resistances in series add; resistances in parallel combine by reciprocals — just like electrical circuits.
\[ \dot{Q} = \frac{\Delta T}{R}, \qquad R_{\text{series}} = \sum R_i \]
Physical meaning
A larger resistance consumes a larger fraction of the total temperature drop. That observation locates the most effective design change before detailed optimization.
Strategy
Steady heat follows one series path through two films and two layers, so use the minimum closing set: total resistance, rate, then node drops.
Givens
- \(A=6.0\) m²; \(T_{\infty,o}=28^\circ\)C, \(T_{\infty,i}=-4^\circ\)C; supplied \(h,L,k\).
Physical/model interpretation
One-dimensional steady conduction, perfect contact, no radiation or thermal bridges; positive heat is into the cold room.
Unit/sign/limit checks
Units: The overall relation gives K/(K/W) = W, while every node drop \(\dot QR_i\) gives W·K/W = K, matching the calculated temperatures.
Signs: Temperatures decrease monotonically from 28°C to −4°C in the declared inward heat direction, and every resistance consumes a positive temperature drop.
Limit: The foam takes 29.66 K of the 32 K total drop because it supplies 92.7% of \(R_t\); removing foam would therefore increase heat gain sharply.
Engineering insight
Steel resistance is negligible; fasteners and joints, omitted here, may dominate an actual panel and require thermal-bridge testing.
Thermal Contact Resistance
Nominally touching solids meet at asperities, constricting heat flow and leaving low-conductivity gaps. \(h_c\) is an empirical joint property, not a material constant: pressure, roughness, flatness, oxidation, and interface material matter.
Thermal Contact Conductance, \(h_c\)
The resistance \(R_c=1/(h_cA)\) creates a finite temperature jump \(\dot QR_c\). Use conductance data matching the surface finish, pressure, temperature, and interstitial medium; extrapolation can be unsafe.
Generalized Thermal Resistance Networks
Side-by-side materials form parallel paths only if they connect the same two temperature nodes. Shared convection films can create lateral coupling; the simple network then becomes an approximation whose quality worsens near path boundaries.
Heat Conduction in Cylinders and Spheres
Radial area varies as \(2\pi rL\) for a cylinder and \(4\pi r^2\) for a sphere. Integrating Fourier’s law therefore gives logarithmic and inverse-radius resistances; inserting an arbitrary area into \(L/kA\) is not generally valid.
Strategy
Radial cylindrical conduction and outside convection are series elements; the surface node follows from the convection drop.
Givens
- \(r_1=0.025\) m, \(r_2=0.055\) m, \(L=10\) m, \(k=0.036\), \(h=9.0\), \(T_\infty=30^\circ\)C, \(T_1=5^\circ\)C.
Physical/model interpretation
Steady radial 1-D model with constant \(k\), negligible pipe/contact resistance and radiation. Positive heat points inward.
Unit/sign/limit checks
Units: Both resistances are K/W; result is W.
Signs: \(30>27.89>5^\circ\)C along inward heat flow.
Limit: If \(h\to\infty\), the outer surface approaches 30°C and film resistance vanishes.
Engineering insight
Vapor-barrier seams and thermal bridges can be colder than this ideal surface; field condensation control needs humidity uncertainty and installation review.
Critical Radius of Insulation
For a cylinder, insulation raises conduction resistance while enlarged area lowers external convection resistance. Differentiating their sum yields \(r_{cr}=k/h\); this result assumes constant \(k,h\), cylindrical geometry, and an outside convection boundary.
Critical Radius of Insulation
Insulating a cylinder (or sphere) only reduces heat loss once the outer radius exceeds a critical value. Below it, added insulation actually increases heat transfer because the gain in exposed surface area outweighs the added conduction resistance.
\[ r_{\text{cr,cyl}} = \frac{k}{h}, \qquad r_{\text{cr,sph}} = \frac{2k}{h} \]
Heat Transfer from Finned Surfaces
A fin adds area but is not isothermal: axial conduction supplies distributed convection. The classic equation assumes steady one-dimensional fin conduction, uniform \(h\), constant \(k\), negligible radiation, and no generation.
The Fin Equation
An element balance yields \(d^2\theta/dx^2-m^2\theta=0\), where \(\theta=T-T_\infty\) and \(m^2=hp/(kA_c)\). The tip boundary selects the solution; an adiabatic-tip approximation is best for a slender fin whose tip area is small.
Strategy
A straight constant-section fin with supplied uniform \(h\) matches the insulated-tip fin solution; calculate \(mL\) before judging performance.
Givens
- \(L=0.040\) m, \(w=0.030\) m, \(t=0.002\) m, \(k=180\), \(h=28\), \(\theta_b=50\) K.
Physical/model interpretation
\(A_c=wt\), \(p=2(w+t)\); steady 1-D conduction, negligible radiation/contact loss, adiabatic tip.
Unit/sign/limit checks
Units: In \(\sqrt{hpkA_c}\theta\), the quantity under the root has units W²/K², so multiplication by the 50 K excess gives W; efficiency and effectiveness are dimensionless ratios.
Signs: With \(\theta_b=T_b-T_\infty=+50\) K, the positive 3.30 W rate leaves the hotter base; reversing the temperature excess would reverse the heat-rate sign.
Limit: \(0<\eta_f=0.914<1\), and the independent check \(\eta_fhA_f\theta_b=3.28\) W agrees within rounding; as \(L\to0\), fin heat transfer tends to zero.
Engineering insight
The fin is thermally effective, but an array also changes airflow and \(h\); spacing, pressure drop, base spreading, extrusion tolerances, and test correlation remain design checks.
Heat Transfer in Common Configurations
Tabulated shape factors compress a particular steady, source-free, constant-\(k\) multidimensional boundary-value problem into \(\dot Q=Sk\Delta T\). Use one only when its geometry and listed restrictions—such as burial depth and length—match.
Problem-solving strategy
- Sketch heat paths and define isothermal nodes and positive heat direction.
- Select geometry-specific resistances and evaluate properties at representative layer temperatures, iterating if needed.
- Combine only true series or parallel elements; retain contact and film resistances when evidence supports them.
- Solve heat rate first, then recover node temperatures from \(\Delta T_i=\dot Q_iR_i\).
- Audit units, node balances, temperature ordering, limiting resistance, and every correlation or shape-factor range.
Chapter recap
- Networks are energy balances arranged around physical paths and isothermal nodes.
- Curved geometry, interfaces, and fins require their own validated resistance models.
- Dominant-resistance and limiting-case checks turn arithmetic into engineering judgment.
Before moving on
- Can you draw and label a mixed network before calculating?
- Can you recover every interface temperature and verify each node balance?
- Can you defend property temperatures and model validity ranges?